Circuit-breaker: Difference between revisions

From Electrical Installation Guide
(update_2018)
(converted syntax for Manual Tocs)
Line 57: Line 57:
{{TableEnd|Tab1265|H20|Functions performed by a circuit-breaker/disconnector}}
{{TableEnd|Tab1265|H20|Functions performed by a circuit-breaker/disconnector}}


{{Manual_TOC |
{{Section-TOC}}
* [[Standards and description of circuit-breakers]]
* [[Fundamental characteristics of a circuit-breaker]]
* [[Other characteristics of a circuit-breaker]]
* [[Selection of a circuit-breaker]]
* [[Coordination between circuit-breakers]]
* [[Discrimination MV/LV in a consumer’s substation]]
* [[Circuit-breakers suitable for IT systems]]
* [[Ultra-rapid circuit breaker]]
}}


[[ru:Автоматический выключатель]]
[[ru:Автоматический выключатель]]
[[zh:断路器]]
[[zh:断路器]]

Revision as of 13:59, 20 December 2019


The circuit-breaker/disconnector fulfills all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist

As shown in Figure H20 the circuit-breaker/ disconnector is the only item of switchgear capable of simultaneously satisfying all the basic functions necessary in an electrical installation.

Moreover, it can, by means of auxiliary units, provide a wide range of other functions, for example: indication (on-off - tripped on fault); undervoltage tripping; remote control… etc. These features make a circuit-breaker/ disconnector the basic unit of switchgear for any electrical installation.

Functions Possible Conditions
Isolation [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Control Functional [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Emergency switching [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (With the possibility of a tripping coil for remote control)
Switching-off for mechanical maintenance [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Protection Overload [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Short-circuit [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Insulation fault [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (With differential-current relay)
Undervoltage [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (With undervoltage-trip coil)
Remote control [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] Added or incorporated
Indication and measurement [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (Generally optional with an electronic tripping device)
Fig. H20 – Functions performed by a circuit-breaker/disconnector

ru:Автоматический выключатель zh:断路器

Share