'''Architecture''': choice of a single-line diagram and technological solutions, from connection to the utility network through to load power supply circuits.<br>'''Main MV/LV distribution''':Level upstream of the architecture, from connection to the network utility through to LV distribution equipment on the site (MLVS – or equivalent).<br>'''MLVS''' –'''Main Low Voltage Switchboard''': Main switchboard downstream of the MV/LV transformer, starting point of power distribution circuits in the installation<br>'''LV power distribution:''' intermediate level in the architecture, downstream of the main level through to the sub-distribution switchboards (spatial and functional distribution of electrical power in the circuits).<br>'''LV terminal distribution:''' Downstream level of the architecture, downstream of the sub-distribution switchboards through to the loads. This level of distribution is not dealt with in this guide.<br>'''Single-line diagram:''' general electrical schematic diagram to represent the main electrical equipment and their interconnection.<br>'''MV substation, transformation substation''': Enclosures grouping together MV equipment and/or MV/LV transformers. These enclosures can be shared or separate, according to the site layout, or the equipment technology. In certain countries, the MV substation is assimilated with the delivery substation.<br>'''Technological solution:''' Resulting from the choice of technology for an installation sub-assembly, from among the different products and equipment proposed by the manufacturer.<br>'''Characteristics:''' Technical or environmental data relative to the installation, enabling the best-suited architecture to be selected.<br>'''Criteria:''' Parameters for assessing the installation, enabling selection of the architecture that is the best-suited to the needs of the customer.
{{def|Architecture|choice of a single-line diagram and technological solutions, from connection to the utility network through load power supply circuits.}}


[[ru:Глоссарий]]
{{def|Main MV/LV distribution| Level upstream of the architecture, from connection to the network utility through to LV distribution equipment on the site (MLVS – or equivalent).}}
 
{{def| MLVS – Main Low Voltage Switchboard| Main switchboard downstream of the MV/LV transformer, starting point of power distribution circuits in the installation}}
 
{{def| LV power distribution| intermediate level in the architecture, downstream of the main level through to the sub-distribution switchboards (spatial and functional distribution of electrical power in the circuits).}}
 
{{def| LV terminal distribution| Downstream level of the architecture, downstream of the sub-distribution switchboards through to the loads. This level of distribution is not dealt with in this guide.}}
 
{{def|Single-line diagram| general electrical schematic diagram to represent the main electrical equipment and their interconnection.}}
 
{{def|MV substation, transformation substation| Enclosures grouping together MV equipment and/or MV/LV transformers. These enclosures can be shared or separate, according to the site layout, or the equipment technology. In certain countries, the MV substation is assimilated with the delivery substation.}}
 
{{def|Technological solution| Resulting from the choice of technology for an installation sub-assembly, from among the different products and equipment proposed by the manufacturer.}}
 
{{def|Characteristics| Technical or environmental data relative to the installation, enabling the best-suited architecture to be selected.}}
 
{{def|Criteria| Parameters for assessing the installation, enabling selection of the architecture that is the best-suited to the needs of the customer.}}

Latest revision as of 09:49, 22 June 2022

Architecture = choice of a single-line diagram and technological solutions, from connection to the utility network through load power supply circuits.

Main MV/LV distribution = Level upstream of the architecture, from connection to the network utility through to LV distribution equipment on the site (MLVS – or equivalent).

MLVS – Main Low Voltage Switchboard = Main switchboard downstream of the MV/LV transformer, starting point of power distribution circuits in the installation

LV power distribution = intermediate level in the architecture, downstream of the main level through to the sub-distribution switchboards (spatial and functional distribution of electrical power in the circuits).

LV terminal distribution = Downstream level of the architecture, downstream of the sub-distribution switchboards through to the loads. This level of distribution is not dealt with in this guide.

Single-line diagram = general electrical schematic diagram to represent the main electrical equipment and their interconnection.

MV substation, transformation substation = Enclosures grouping together MV equipment and/or MV/LV transformers. These enclosures can be shared or separate, according to the site layout, or the equipment technology. In certain countries, the MV substation is assimilated with the delivery substation.

Technological solution = Resulting from the choice of technology for an installation sub-assembly, from among the different products and equipment proposed by the manufacturer.

Characteristics = Technical or environmental data relative to the installation, enabling the best-suited architecture to be selected.

Criteria = Parameters for assessing the installation, enabling selection of the architecture that is the best-suited to the needs of the customer.