|
|
(9 intermediate revisions by 2 users not shown) |
Line 1: |
Line 1: |
| {{modification_warning}}
| | <includeonly> |
| <div class="noprint"> | | <!---------- modify the chapter letter below, to adapt to each chapter ----------> |
| <div class="template_div"> | | {{#vardefine:letter|F}} |
| {| class="template_table" | | <!----------------------------------------------------------------------------------------------------> |
| | | [[General rules of electrical installation design]]
| | {{#isin:{{#hierarchyParent:{{#titleparts:{{FULLPAGENAME}}}}|{{MediaWiki:eig-hierarchy}}|hierarchyargtype=wikitext|link=none}}}} |
| |-
| | {{#set:Has chapter letter={{#var:letter}}}} |
| | | [[Connection to the MV utility distribution network]]
| | {{#vardefine:menuMsg|eig-ch-menu-{{#var:letter}}}} |
| |-
| | {{#sideSummary:{{#var:menuMsg}}}} |
| | | [[Connection to the LV utility distribution network]]
| | {{ch-category|{{#var:letter}}}}[[Category:eig-content-pages]]</includeonly><noinclude>[[Category:eig-ch-menus]]<templatedata> |
| |-
| | { |
| | | [[MV and LV architecture selection guide for buildings]]
| | "params": {}, |
| |-
| | "description": "This template is used to add common information to pages of a same chapter: semantic property for parent page, chapter category, and sidemenu" |
| | | [[LV Distribution]]
| | } |
| |-
| | </templatedata> |
| | id="chapter" | [[Protection against electric shocks and electric fires]]
| | </noinclude> |
| |-
| |
| | class="selected" |
| |
| * [[Protection against electric shock]]
| |
| * [[Types of protection against electric shock]]
| |
| * [[Additional protection: High sensitivity RCDs]]
| |
| * [[Implementation of the TT system]]
| |
| ** [[TT system - Principle|Principle]]
| |
| ** [[TT system - Practical aspects|Practical aspects]]
| |
| * [[Implementation of the TN system]]
| |
| ** [[TN system - Principle|Principle]]
| |
| ** [[TN system - Preliminary conditions|Preliminary conditions]]
| |
| ** [[TN system - Earth-fault current calculation|Earth-fault current calculation]]
| |
| ** [[TN system - High fault current-loop impedance|High fault current-loop impedance]]
| |
| * [[Implementation of the IT system]]
| |
| ** [[IT system - Principle|Principle]]
| |
| ** [[IT system - Fault protection|Fault protection]]
| |
| ** [[IT system - Implementation of protections|Implementation of protections]]
| |
| ** [[IT system - Practical aspects|Practical aspects]]
| |
| * [[Residual Current Devices (RCDs)]]
| |
| ** [[Description of RCDs]]
| |
| ** [[Form factors of RCDs]]
| |
| ** [[Types of RCDs]]
| |
| ** [[Sensitivity of RCDs to disturbances]]
| |
| ** [[Coordination of residual current protective devices]]
| |
| * [[Other protective measures against electric shocks]]
| |
| ** [[Extra Low Voltage (ELV)]]
| |
| ** [[The electrical separation of circuits]]
| |
| ** [[Class II equipment]]
| |
| ** [[Out-of-arm’s reach or interposition of obstacles]]
| |
| * [[Protection against electrical fire risks]]
| |
| ** [[Fires of electrical origin]]
| |
| ** [[Protection against fire due to earth faults]]
| |
| ** [[Protection against arc faults in cables and connections (AFDD)]]
| |
| ** [[Protection against electrical fire risks - synthesis]]
| |
| |- | |
| | | [[Sizing and protection of conductors]] | |
| |-
| |
| | | [[LV switchgear: functions and selection]]
| |
| |- | |
| | | [[Overvoltage protection]]
| |
| |-
| |
| | | [[Energy Efficiency in electrical distribution]]
| |
| |-
| |
| | | [[Power Factor Correction]]
| |
| |-
| |
| | | [[Power harmonics management]]
| |
| |-
| |
| | | [[Characteristics of particular sources and loads]]
| |
| |-
| |
| | | [[PhotoVoltaic (PV) installation]]
| |
| |-
| |
| | | [[Residential and other special locations]]
| |
| |-
| |
| | | [[ElectroMagnetic Compatibility (EMC)]]
| |
| |-
| |
| | | [[Measurement]]
| |
| |-
| |
| |-
| |
| |}
| |
| </div> | |
| [[Category:Chapter - Protection against electric shocks and electric fires]]
| |
| </div> | |