Presence of an Uninterruptible Power Supply (UPS): Difference between revisions

From Electrical Installation Guide
Home > MV and LV architecture selection guide for buildings > Choice of architecture details > Presence of an Uninterruptible Power Supply (UPS)
m (r2.7.2) (robot Adding: zh:不间断电源 (UPS) 的设置)
m (cleaned up source: table format, etc ...)
Line 1: Line 1:
{{Menu_MV_&_LV_architecture_selection_guide}}
{{Menu_MV_and_LV_architecture_selection_guide}}
<br>
<br>
The electrical power from a UPS is supplied from a storage unit: batteries or inertia wheel. This system allows us to avoid any power failure. The back-up time of the system is limited: from several minutes to several hours.<br>The simultaneous presence of a back-up generator and a UPS unit is used for permanently supply loads for which no failure is acceptable ('''Fig. D17'''). The back-up time of the battery or the inertia wheel must be compatible with the maximum time for the generator to start up and be brought on-line.<br>A UPS unit is also used for supply power to loads that are sensitive to disturbances (generating a “clean” voltage that is independent of the network).<br>Main characteristics to be considered for implementing a UPS:  
The electrical power from a UPS is supplied from a storage unit: batteries or inertia wheel. This system allows us to avoid any power failure. The back-up time of the system is limited: from several minutes to several hours.<br>The simultaneous presence of a back-up generator and a UPS unit is used for permanently supply loads for which no failure is acceptable ('''Fig. D17'''). The back-up time of the battery or the inertia wheel must be compatible with the maximum time for the generator to start up and be brought on-line.<br>A UPS unit is also used for supply power to loads that are sensitive to disturbances (generating a “clean” voltage that is independent of the network).<br>Main characteristics to be considered for implementing a UPS:  
Line 10: Line 10:
----
----


<br>[[Image:FigD17.jpg|left]] <br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>'''''Fig. D17:'''&nbsp;Example of connection for a UPS''
[[File:FigD17.jpg|none]]
'''''Fig. D17:'''&nbsp;Example of connection for a UPS''


[[ru:Использование источников бесперебойного питания (ИБП)]]
[[ru:Использование источников бесперебойного питания (ИБП)]]
[[zh:不间断电源 (UPS) 的设置]]
[[zh:不间断电源 (UPS) 的设置]]

Revision as of 13:10, 15 November 2013


The electrical power from a UPS is supplied from a storage unit: batteries or inertia wheel. This system allows us to avoid any power failure. The back-up time of the system is limited: from several minutes to several hours.
The simultaneous presence of a back-up generator and a UPS unit is used for permanently supply loads for which no failure is acceptable (Fig. D17). The back-up time of the battery or the inertia wheel must be compatible with the maximum time for the generator to start up and be brought on-line.
A UPS unit is also used for supply power to loads that are sensitive to disturbances (generating a “clean” voltage that is independent of the network).
Main characteristics to be considered for implementing a UPS:

  • Sensitivity of loads to power interruptions,
  • Sensitivity of loads to disturbances.

The presence of a UPS unit is essential if and only if no failure is acceptable.