EMC implementation - Communication networks: Difference between revisions
CleanUp2016 (talk | contribs) (Cleanup_2016) |
(→Protection against coils disturbances: test centering text in column (using modified template Table_HC2, to be able to include additional styling info)) |
||
Line 45: | Line 45: | ||
! Contact fall time | ! Contact fall time | ||
|- | |- | ||
| {{Table_HC2}} | [[File:DB422783.png]] | | {{Table_HC2|text-align:center;}} | [[File:DB422783.png]] | ||
| {{Table_HC2}} | R-C network | | {{Table_HC2}} | R-C network | ||
| {{Table_HC2}} | Y | | {{Table_HC2}} | Y | ||
Line 52: | Line 52: | ||
| {{Table_HC2}} | 1 to 2 times the standard time | | {{Table_HC2}} | 1 to 2 times the standard time | ||
|- | |- | ||
| {{Table_HC2}} | [[File:DB422784.png]] | | {{Table_HC2|text-align:center;}} | [[File:DB422784.png]] | ||
| {{Table_HC2}} | Metal Oxide Varistor | | {{Table_HC2}} | Metal Oxide Varistor | ||
| {{Table_HC2}} | Y | | {{Table_HC2}} | Y | ||
Line 59: | Line 59: | ||
| {{Table_HC2}} | 1.1 to 1.5 times the standard time | | {{Table_HC2}} | 1.1 to 1.5 times the standard time | ||
|- | |- | ||
| {{Table_HC2}} | [[File:DB422785.png]] | | {{Table_HC2|text-align:center;}} | [[File:DB422785.png]] | ||
| {{Table_HC2}} | Transient Voltage | | {{Table_HC2}} | Transient Voltage | ||
Suppression Diode <br> | Suppression Diode <br> | ||
Line 68: | Line 68: | ||
| {{Table_HC2}} | 1.1 to 1.5 times the standard time | | {{Table_HC2}} | 1.1 to 1.5 times the standard time | ||
|- | |- | ||
| [[File:DB422786.png]] | | style="text-align:center;" | [[File:DB422786.png]] | ||
| Transient Voltage | | Transient Voltage | ||
Suppression Diode <br> | Suppression Diode <br> | ||
Line 77: | Line 77: | ||
| 3 to 10 times the standard time | | 3 to 10 times the standard time | ||
|- | |- | ||
| [[File:DB422787.png]] | | style="text-align:center;" | [[File:DB422787.png]] | ||
| Free wheeling diode | | Free wheeling diode | ||
| N | | N | ||
Line 84: | Line 84: | ||
| 3 to 10 times the standard time | | 3 to 10 times the standard time | ||
|- | |- | ||
| [[File:DB422788.png]] | | style="text-align:center;" | [[File:DB422788.png]] | ||
| Resistor | | Resistor | ||
| Y | | Y |
Revision as of 07:05, 5 September 2017
It is highly recommended to follow the European Standards EN 50173 series to perform Information Technology cablings.
To ensure a reliable data transmission, the quality of the whole link shall be homogeneous. That means the category of the different cables shall be the same, the connecting interfaces shall be adapted to the cables.
Cables and connections of different categories may be mixed within a channel however the resultant performance will be determined by the category of the lowest performing component.
The shield continuity of the whole link (patch cords, Terminal Outlets, horizontal cable) shall be ensured and controlled by tests.
The Terminal Outlets (TO) could be used to earth the screen terminations in the cabinet. The choice of these TO is very important.
Communication networks are mostly extensive. They interconnect equipment located in different areas where the feeding power supplies could have different earthing systems.
If these different areas are not well equipotential, harsh transient currents could appear (lightning, main power fault, etc.) causing high voltage potential differences between interconnected equipment.
Communication interfaces (board, module, etc.) could be disturbed or damaged by this common mode over voltages.
The use of TN-S earthing system and well equipotential installation minimize this issue.
In any case, the use of Surge Protective Device (SPD) installed in Common Mode and/or Differential Mode is recommended.
If the different areas/zones are not equipotential, if the power supply earthing system is TN-C or IT, or if there is a doubt and the previous 2 points, optical fiber links are highly recommended.
To avoid electrical safety issue, the optical fiber link should not have any metallic parts.
Protection against coils disturbances
AC and mostly DC Coils (relay, contactor, actuator, etc.) are very disturbing sources.
To minimize these High Frequency disturbances the following solutions could be implemented. (In grey, the preferred choice).
To be efficient, the TVS shall be installed closely to the coil.
ru:Конструктивное исполнение ЭМС - сети связи zh:电磁兼容实施 - 通信网络