! colspan=" | ! colspan="4" | Equipment and appliances || cos φ || tan φ | ||
|- | |- | ||
| | | rowspan="5" | Motor | ||
| rowspan="5" |Common induction motor | |||
| rowspan="5"| loaded at || 0 % || 0.17 || 5.80 | |||
| loaded at | |||
| | |||
0% | |||
| | |||
0.17 | |||
| | |||
5.80 | |||
|- | |- | ||
| | | 25% || 0.55 || 1.52 | ||
| | |||
| | |||
| | |||
|- | |- | ||
| | | 50 % || 0.73 || 0.94 | ||
| | |||
| | |||
| | |||
|- | |- | ||
| | | 75 % || 0.80 || 0.75 | ||
| | |||
| | |||
0. | |||
| | |||
|- | |- | ||
| | | 100 % || 0.85 || 0.62 | ||
|- | |||
| rowspan="4" |Lamps | |||
| | | colspan="3" |Incandescent lamps | ||
| | | 1.0 || 0 | ||
| 0.8 | |- | ||
| 0. | | colspan="3" |Fluorescent lamps (uncompensated) | ||
| | | 0.5 || 1.73 | ||
|- | |||
| colspan="3" |Fluorescent lamps (compensated) | |||
| 0.93 || 0.39 | |||
|- | |||
| colspan="3" |Discharge lamps | |||
| 0.4 to 0.6 || 2.29 to 1.33 | |||
|- | |||
| rowspan="4" |Ovens | |||
| colspan="3" |Ovens using resistance elements | |||
| 1.0 || 0 | |||
|- | |||
| colspan="3" |Induction heating ovens (compensated) | |||
| 0.85 || 0.62 | |||
|- | |||
| colspan="3" |Dielectric type heating ovens | |||
| 0.85 || 0.62 | |||
|- | |||
| colspan="3" |Arc furnace | |||
|0.8 | |||
|0.75 | |||
|- | |||
| rowspan="4" |Welding | |||
| colspan="3" |Resistance-type soldering machines | |||
| 0.8 to 0.9 || 0.75 to 0.48 | |||
|- | |||
| colspan="3" |Fixed 1-phase arc-welding set | |||
| 0.5 || 1.73 | |||
|- | |||
| colspan="3" |Arc-welding motor-generating set | |||
| 0.7 to 0.9 || 1.02 to 0.48 | |||
|- | |||
| colspan="3" |Arc-welding transformer-rectifier set | |||
| 0.7 to 0.8 || 1.02 to 0.75 | |||
|- | |||
{{TableEnd|Tab1331|L6|Values of cos φ and tan φ for commonly-used equipment}} | |||
[[ru:Практические значения коэффициента мощности]] | [[ru:Практические значения коэффициента мощности]] | ||
[[zh:功率因数的实际值]] | [[zh:功率因数的实际值]] |
Revision as of 00:02, 7 December 2016
Average power factor values for the most commonly-used equipment and appliances
(see Fig. L6)
Equipment and appliances | cos φ | tan φ | |||
---|---|---|---|---|---|
Motor | Common induction motor | loaded at | 0 % | 0.17 | 5.80 |
25% | 0.55 | 1.52 | |||
50 % | 0.73 | 0.94 | |||
75 % | 0.80 | 0.75 | |||
100 % | 0.85 | 0.62 | |||
Lamps | Incandescent lamps | 1.0 | 0 | ||
Fluorescent lamps (uncompensated) | 0.5 | 1.73 | |||
Fluorescent lamps (compensated) | 0.93 | 0.39 | |||
Discharge lamps | 0.4 to 0.6 | 2.29 to 1.33 | |||
Ovens | Ovens using resistance elements | 1.0 | 0 | ||
Induction heating ovens (compensated) | 0.85 | 0.62 | |||
Dielectric type heating ovens | 0.85 | 0.62 | |||
Arc furnace | 0.8 | 0.75 | |||
Welding | Resistance-type soldering machines | 0.8 to 0.9 | 0.75 to 0.48 | ||
Fixed 1-phase arc-welding set | 0.5 | 1.73 | |||
Arc-welding motor-generating set | 0.7 to 0.9 | 1.02 to 0.48 | |||
Arc-welding transformer-rectifier set | 0.7 to 0.8 | 1.02 to 0.75 |