User:LMischler/Img-2018-N: Difference between revisions

From Electrical Installation Guide
(manually changed 4 images from png to svg, and 1 image from svg to png)
(update as latest 2018 book (modified images))
 
Line 39: Line 39:
{{FigImage|DB422683_EN|svg|N44|Depiction of earth leakage current test results  '''(DB422683_EN)'''}}
{{FigImage|DB422683_EN|svg|N44|Depiction of earth leakage current test results  '''(DB422683_EN)'''}}
{{FigImage|DB422684_EN|svg|N45|Current at switching “on” according to voltage angle (zero crossing and 90°) '''(DB422684_EN)'''}}
{{FigImage|DB422684_EN|svg|N45|Current at switching “on” according to voltage angle (zero crossing and 90°) '''(DB422684_EN)'''}}
[[File:DB422685_EN.svg|'''(DB422685_EN)''']]
{{Gallery|N46|Coordination between circuit breaker and luminaires LED||
[[File:DB422686_EN.svg|'''(DB422686_EN)''']]
|DB422685_EN.svg||'''(DB422685_EN)'''
[[File:DB422687_EN.svg|'''(DB422687_EN)''']]
|DB422686_EN.svg||'''(DB422686_EN)'''
[[File:DB431033.png]]
|DB422687_EN.svg||'''(DB422687_EN)'''
{{FigImage|DB431074|svg|N50|????? '''(DB431074)'''}}
|DB422688_EN.svg||'''(DB422688_EN)'''}}
[[File:DB431033.png|'''(DB431033)''']]
[[File:DB431033.png|'''(DB431033)''']]
{{FigImage|DB431074|svg|N50|Direct and indirect lightining strikes '''(DB431074)'''}}
{{FigImage|PB119915|jpg|N51|Type 2 surge protection device '''(PB119915)'''}}
{{FigImage|PB119915|jpg|N51|Type 2 surge protection device '''(PB119915)'''}}
{{FigImage|PB107131-35|jpg|N52|Surge arrester for information circuit '''(PB107131-35)'''}}
{{FigImage|PB107131-35|jpg|N52|Surge arrester for information circuit '''(PB107131-35)'''}}
Line 66: Line 69:
|PB116814.jpg||'''(PB116814)'''}}
|PB116814.jpg||'''(PB116814)'''}}
{{FigImage|PB116815|jpg|N69|s.i. residual current devices with immunity against impulse currents (Schneider-Electric brand) '''(PB116815)'''}}
{{FigImage|PB116815|jpg|N69|s.i. residual current devices with immunity against impulse currents (Schneider-Electric brand) '''(PB116815)'''}}
{{FigImage|PB116816|jpg|N72|The main functions of an emergency lighting system '''(PB116816)'''}}
{{FigImage|DB431084|svg|N72|The main functions of an emergency lighting system '''(DB431084)'''}}
{{FigImage|DB422689_EN|svg|N74|Direct on-line starting current characteristics of an induction motor '''(DB422689_EN)'''}}
{{FigImage|DB422689_EN|svg|N74|Direct on-line starting current characteristics of an induction motor '''(DB422689_EN)'''}}
{{FigImage|DB422690_EN|svg|N77|Reduced motor lifetime as a consequence of overheating '''(DB422690_EN)'''}}
{{FigImage|DB422690_EN|svg|N77|Reduced motor lifetime as a consequence of overheating '''(DB422690_EN)'''}}

Latest revision as of 17:42, 11 June 2018

Fig. N1 – Example of circuits supplied from a transformer or from an alternator (DB422640_EN)
Fig. N2 – Block diagram of a generator set (DB422641_EN)
Fig. N3 – Example of an overload curve t = f(I/In) (DB422642_EN)
Fig. N4 – Short-circuit current level during the 3 phases (DB422643_EN)
Fig. N6 – Example of a priority services switchboard supplied (in an emergency) from a standby generator set (DB422644_EN)
Fig. N7 – Restarting of priority motors (ΣP > 1/3 Pn) (DB422645_EN)
Fig. N8 – Generator set- UPS combination for Quality energy (DB422646_EN)
Fig. N10 – Progressive starting of a type 2 UPS rectifier (DB422647_EN)
Fig. N11 – Chart for calculating harmonic distorsion (DB422648_EN)
Fig. N12 – Insulation fault inside a generator (DB422649_EN)
Fig. N13 – Energy transfer direction – Generator Set as a generator (DB422650_EN)
Fig. N14 – Energy transfer direction – Generator Set as a load (DB422651_EN)
Fig. N15 – Availability of electrical power (DB422652_EN)
Fig. N16 – UPS operating in passive standby mode (DB422653_EN)
Fig. N17 – UPS operating in line-interactive mode (DB422654_EN)
Fig. N18 – UPS operating in double-conversion (on-line) mode (DB422655_EN)
Fig. N20 – Shelf mounting (DB422656)
Fig. N21 – Tier mounting (DB422657)
Fig. N22 – Cabinet mounting (DB422658)
Fig. N24 – The essential points that must be connected in system earthing arrangements (DB422659_EN)
Fig. N25 – Circuit breakers are submitted to a variety of situations (DB422660_EN)
Fig. N27 – Generator during short-circuit (DB422661_EN)
Fig. N28 – Current to be taken into account for the selection of the wire connections (DB422662_EN)
Fig. N30 – Ready-to-use UPS unit (with DIN module) (PB116809)
Fig. N31 – UPS unit achieving disponibility and quality of computer system power supply (PB116810)
Fig. N32 – Transformer-energizing inrush current (DB422663_EN)
Fig. N33 – Tripping characteristic of a Compact NSX with electronic trip-unit (DB422664_EN)
Fig. N34 – Tripping characteristic of a Acti 9 curve D (DB422665_EN)
Fig. N35 – Example (DB422666_EN)

(DB431035)

Fig. N36 – Lighting technologies (DB422667_EN)
Fig. N37 – LED lamps (DB422671_EN)
Fig. N39 – Discharge lamps (DB422670)
Fig. N42 – A LED is just one small element within a larger construct that is sold commercially as a lamp or an assembled luminaire (DB422681_EN)
Fig. N43 – Illustration of four states of a LED being energized (DB422682_EN)
Fig. N44 – Depiction of earth leakage current test results (DB422683_EN)
Fig. N45 – Current at switching “on” according to voltage angle (zero crossing and 90°) (DB422684_EN)

(DB431033) (DB431033)

Fig. N50 – Direct and indirect lightining strikes (DB431074)
Fig. N51 – Type 2 surge protection device (PB119915)
Fig. N52 – Surge arrester for information circuit (PB107131-35)
Fig. N53 – Voltage threshold tripping device (DB431075)
Fig. N54 – Miniature circuit breaker, surge protection device and voltage threshold tripping device (PB106392)
Fig. N55 – Outdoor LED lighting protection (DB431083)
Fig. N57 – Percentage of 3rd harmonic current as a function of the power applied to an incandescent lamp using an electronic dimmer switch (DB422674_EN)
Fig. N58 – Magnetic ballasts (DB422675)
Fig. N59 – The various compensation layouts (DB422676_EN)
Fig. N62 – Electronic ballast (DB422679)
Fig. N64 – Shape of the current drawn by a compact fluorescent lamp (DB422680_EN)
Fig. N69 – s.i. residual current devices with immunity against impulse currents (Schneider-Electric brand) (PB116815)
Fig. N72 – The main functions of an emergency lighting system (DB431084)
Fig. N74 – Direct on-line starting current characteristics of an induction motor (DB422689_EN)
Fig. N77 – Reduced motor lifetime as a consequence of overheating (DB422690_EN)
Fig. N78 – Tripping curves of overload relays (DB422691_EN)
Fig. N80 – Example of intelligent motor management system with “Advanced Plus” and “High performance” protection and monitoring functions (TeSys T Schneider Electric) (PB116817)
Fig. N85 – Tripping characteristics of a circuit breaker + contactor + thermal relay (DB422695_EN)
Fig. N86 – Example of a CPS modularity (TeSys U starter controller by Schneider Electric) (DB422696_EN)
Fig. N88 – Example of motor control and protection architecture (DB422697_EN)
Fig. N89 – Example of iPMCC: Okken switchboard and drawers by Schneider Electric (DB422698_EN)