The SPD chiefly consists of (see {{FigRef|J50}}):
__TOC__
 
The SPD chiefly consists of (see {{FigRef|J48}}):


'''1)''' one or more nonlinear components: the live part (varistor, gas discharge tube, etc.);
'''1)''' one or more nonlinear components: the live part (varistor, gas discharge tube, etc.);
Line 14: Line 11:
'''4)''' an external SCPD which provides protection against short circuits (this device can be integrated into the SPD).  
'''4)''' an external SCPD which provides protection against short circuits (this device can be integrated into the SPD).  


{{FigImage|DB422510|svg|J48|Diagram of a SPD}}
{{FigImage|DB422510|svg|J50|Diagram of a SPD}}


== Technology of the live part ==
== Technology of the live part ==
Line 25: Line 22:
The table below shows the characteristics and the arrangements of 3 commonly used technologies.  
The table below shows the characteristics and the arrangements of 3 commonly used technologies.  


{{TableStart|Tab1302|5col}}
{{tb-start|id=Tab1302|num=J51|title=Summary performance table|cols=5}}
{| class="wikitable"
|-
|-
! Component  
! Component  
Line 34: Line 32:
! Encapsulated spark gap and varistor in parallel
! Encapsulated spark gap and varistor in parallel
|-
|-
| {{Table_HC2}} | '''Characteristics'''  
| {{tb-HC2}} | '''Characteristics'''  
!  
!  
!  
!  
Line 41: Line 39:
!  
!  
|-
|-
| {{Table_HC2}} |
| {{tb-HC2}} |
| valign="middle" | [[File:DB422511.svg]]
| valign="middle" | [[File:DB422511.png]]
| valign="middle" | [[File:DB422512.svg]]
| valign="middle" | [[File:DB422512.png]]
| [[File:DB422513.svg]]  
| [[File:DB422513.png]]  
| [[File:DB422514.svg]]  
| [[File:DB422514.png]]  
| [[File:DB422515.svg]]
| [[File:DB422515.png]]
|-
|-
| {{Table_HC2}} | '''Operating mode'''  
| {{tb-HC2}} | '''Operating mode'''  
| Voltage switching  
| Voltage switching  
| Voltage switching  
| Voltage switching  
Line 55: Line 53:
| Voltage-switching and -limiting in parallel
| Voltage-switching and -limiting in parallel
|-
|-
| {{Table_HC2}} | '''Operating curves'''  
| {{tb-HC2}} | '''Operating curves'''  
| valign="middle" align="center" colspan="2" | [[File:DB422516.svg]]
| valign="middle" align="center" colspan="2" | [[File:DB422516.png]]
| valign="middle" align="center" | [[File:DB422517.svg]]
| valign="middle" align="center" | [[File:DB422517.png]]
| {{Table_HC2}} |
| {{tb-HC2}} |
| {{Table_HC2}} |
| {{tb-HC2}} |
|-
|-
| {{Table_HC2}} | '''Application'''  
| {{tb-HC2}} | '''Application'''  
|  
|  
*Telecom network  
*Telecom network  
Line 73: Line 71:
| LV network
| LV network
|-
|-
| {{Table_HC2}} | '''SPD Type'''  
| {{tb-HC2}} | '''SPD Type'''  
| Type 2  
| Type 2  
| Type 1  
| Type 1  
Line 79: Line 77:
| Type 1+ Type 2  
| Type 1+ Type 2  
| Type 1+ Type 2
| Type 1+ Type 2
|-
|}
{{TableEnd|Tab1302|J49|Summary performance table}}


'''Note:''' Two technologies can be installed in the same SPD (see {{FigRef|J50}})
'''Note:''' Two technologies can be installed in the same SPD (see {{FigRef|J52}})


{{Gallery|J50|The Schneider Electric brand iPRD SPD incorporates a gas discharge tube between neutral and earth and varistors between phase and neutral|215px|
{{Gallery|J52|The Schneider Electric brand iPRD SPD incorporates a gas discharge tube between neutral and earth and varistors between phase and neutral||
|PB116777.jpg||
|PB116777.jpg||
|DB422518.svg||}}
|DB422518.svg||}}
[[zh:浪涌保护器的部件]]

Latest revision as of 17:50, 20 December 2019

The SPD chiefly consists of (see Fig. J50):

1) one or more nonlinear components: the live part (varistor, gas discharge tube, etc.);

2) a thermal protective device (internal disconnector) which protects it from thermal runaway at end of life (SPD with varistor);

3) an indicator which indicates end of life of the SPD;

Some SPDs allow remote reporting of this indication;

4) an external SCPD which provides protection against short circuits (this device can be integrated into the SPD).

Fig. J50 – Diagram of a SPD

Technology of the live part

Several technologies are available to implement the live part. They each have advantages and disadvantages:

  • Zener diodes;
  • The gas discharge tube (controlled or not controlled);
  • The varistor (zinc oxide varistor).

The table below shows the characteristics and the arrangements of 3 commonly used technologies.

Fig. J51 – Summary performance table
Component Gas Discharge Tube (GDT) Encapsulated spark gap Zinc oxide varistor GDT and varistor in series Encapsulated spark gap and varistor in parallel
Characteristics
DB422511.png DB422512.png DB422513.png DB422514.png DB422515.png
Operating mode Voltage switching Voltage switching Voltage limiting Voltage-switching and -limiting in series Voltage-switching and -limiting in parallel
Operating curves DB422516.png DB422517.png
Application
  • Telecom network
  • LV network

(associated with varistor)

LV network LV network LV network LV network
SPD Type Type 2 Type 1 Type 1 or Type 2 Type 1+ Type 2 Type 1+ Type 2

Note: Two technologies can be installed in the same SPD (see Fig. J52)