The electrical power from a UPS is supplied from a storage unit: batteries or inertia wheel. This system prevent any power failure. The back-up time of the system is limited: from several minutes to several hours.
The electrical power from a UPS is supplied from a storage unit: batteries or inertia wheel. This system prevent any power failure. The back-up time of the system is limited: from several minutes to several hours.


The simultaneous presence of a back-up generator and a UPS unit is used for permanently supply loads for which no failure is acceptable '''(Fig. D19)'''. The back-up time of the battery must be compatible with the maximum time for the generator to start up and take over the load supply.
The simultaneous presence of a back-up generator and a UPS unit is used for permanently supply loads for which no failure is acceptable ({{FigRef|D19}}). The back-up time of the battery must be compatible with the maximum time for the generator to start up and take over the load supply.


A UPS unit is also used to supply loads that are sensitive to power quality (generating a “clean” voltage that is independent of the network).
A UPS unit is also used to supply loads that are sensitive to power quality (generating a “clean” voltage that is independent of the network).


Main characteristics to be considered for implementing a UPS:
Main characteristics to be considered for implementing a UPS:
 
* Sensitivity of loads to power interruptions (see [[Electrical installation characteristics|Voltage Interruption Sensitivity]] for definition),
* Sensitivity of loads to power interruptions (see § 3.9 for definition),
* Sensitivity of loads to disturbances (see [[Electrical installation characteristics|Disturbance sensitivity]] for definition).
* Sensitivity of loads to disturbances (see § 3.10 for definition).


The presence of a UPS unit is essential if and only if no failure is acceptable.
The presence of a UPS unit is essential if and only if no failure is acceptable.


----
{{FigImage|DB422133_EN|svg|D19|Example of connection for a UPS}}
 
[[File:FigD17.jpg|none]]
'''''Fig. D19:''''' ''Example of connection for a UPS''
 
[[ru:Использование источников бесперебойного питания (ИБП)]]
[[zh:不间断电源 (UPS) 的设置]]

Latest revision as of 09:48, 22 June 2022

The electrical power from a UPS is supplied from a storage unit: batteries or inertia wheel. This system prevent any power failure. The back-up time of the system is limited: from several minutes to several hours.

The simultaneous presence of a back-up generator and a UPS unit is used for permanently supply loads for which no failure is acceptable (Fig. D19). The back-up time of the battery must be compatible with the maximum time for the generator to start up and take over the load supply.

A UPS unit is also used to supply loads that are sensitive to power quality (generating a “clean” voltage that is independent of the network).

Main characteristics to be considered for implementing a UPS:

The presence of a UPS unit is essential if and only if no failure is acceptable.