Template:Menu Sizing and protection of conductors: Difference between revisions

From Electrical Installation Guide
(Updated chapter navigation template according to guide 2013 (plus clean-up))
m (1 revision imported: move to MW1.39)
 
(19 intermediate revisions by 4 users not shown)
Line 1: Line 1:
<div class="noprint">
<includeonly>
{| cellpadding="1" style="float: {{{side|right}}}; border: 1px solid #8888aa; background: #f7f8ff; padding: 5px; font-size: 95%; margin: 0 15px 0 15px; width:250px;"
<!---------- modify the chapter letter below, to adapt to each chapter ---------->
| style="background: #ccf; text-align: center;" | [[General rules of electrical installation design]]
{{#vardefine:letter|G}}
|-
<!---------------------------------------------------------------------------------------------------->
| style="background: #ccf; text-align: center;" | [[Connection to the MV utility distribution network]]
{{#isin:{{#hierarchyParent:{{#titleparts:{{FULLPAGENAME}}}}|{{MediaWiki:eig-hierarchy}}|hierarchyargtype=wikitext|link=none}}}}
|-
{{#set:Has chapter letter={{#var:letter}}}}
| style="background: #ccf; text-align: center;" | [[Connection to the LV utility distribution network]]
{{#vardefine:menuMsg|eig-ch-menu-{{#var:letter}}}}
|-
{{#sideSummary:{{#var:menuMsg}}}}
| style="background: #ccf; text-align: center;" | [[MV and LV architecture selection guide]]
{{ch-category|{{#var:letter}}}}[[Category:eig-content-pages]]</includeonly><noinclude>[[Category:eig-ch-menus]]<templatedata>
|-
{
| style="background: #ccf; text-align: center;" | [[LV Distribution]]
"params": {},
|-
"description": "This template is used to add common information to pages of a same chapter: semantic property for parent page, chapter category, and sidemenu"
| style="background: #ccf; text-align: center;" | [[Protection against electric shocks]]
}
|-
</templatedata>
| style="background: #ccf; text-align: center;" id="chapter"| [[Sizing and protection of conductors]]
</noinclude>
|-
||
* [[Conductor sizing and protection ]]
** [[Conductor sizing: methodology and definition]]
** [[Overcurrent protection principles]]
** [[Practical values for a protective scheme]]
** [[Location of protective devices]]
** [[Conductors in parallel]]
* [[Practical method for determining the smallest allowable cross-sectional area of circuit conductors]]
** [[General method for cable sizing]]
** [[Recommended simplified approach for cable sizing]]
** [[Busbar trunking systems]]
* [[Determination of voltage drop]]
** [[Maximum voltage drop limit]]
** [[Calculation of voltage drop in steady load conditions]]
* [[Short-circuit current]]
** [[Short-circuit current at the secondary terminals of a MV/LV distribution transformer]]
** [[3-phase short-circuit current (Isc) at any point within a LV installation]]
** [[Isc at the receiving end of a feeder as a function of the Isc at its sending end]]
* [[Particular cases of short-circuit current]]
** [[Calculation of minimum levels of short-circuit current]]
** [[Verification of the withstand capabilities of cables under short-circuit conditions]]
* [[Protective earthing conductor]]
** [[Connection and choice for protective earthing conductor]]
** [[Sizing of protective earthing conductor]]
** [[Protective conductor between MV/LV transformer and the main general distribution board (MGDB)]]
** [[Equipotential conductor]]
* [[The neutral conductor]]
** [[Sizing the neutral conductor]]
** [[Protection of the neutral conductor]]
** [[Breaking of the neutral conductor]]
** [[Isolation of the neutral conductor]]
* [[Worked example of cable calculation]]
|-
| style="background: #ccf; text-align: center;" | [[LV switchgear: functions and selection]]
|-
| style="background: #ccf; text-align: center;" | [[Overvoltage protection]]
|-
| style="background: #ccf; text-align: center;" | [[Energy Efficiency in electrical distribution]]
|-
| style="background: #ccf; text-align: center;" | [[Power Factor Correction]]
|-
| style="background: #ccf; text-align: center;" | [[Power harmonics management]]
|-
| style="background: #ccf; text-align: center;" | [[Characteristics of particular sources and loads]]
|-
| style="background: #ccf; text-align: center;" | [[PhotoVoltaic (PV) installation]]
|-
| style="background: #ccf; text-align: center;" | [[Residential and other special locations]]
|-
| style="background: #ccf; text-align: center;" | [[ElectroMagnetic Compatibility (EMC)]]
|-
|}
</div>
 
[[Category:Chapter - Sizing and protection of conductors]]

Latest revision as of 13:45, 26 January 2024

This template is used to add common information to pages of a same chapter: semantic property for parent page, chapter category, and sidemenu

Template parameters

ParameterDescriptionTypeStatus
No parameters specified