== Definition  ==
== Definition  ==


Line 12: Line 13:
== Examples  ==
== Examples  ==


(see '''Fig. R28''')  
(see '''Fig. R38''')  


*Nearby cables subjected to rapid current variations (di/dt)  
*Nearby cables subjected to rapid current variations (di/dt)  
Line 22: Line 23:
*Inductors
*Inductors


----
<br>[[Image:Fig_R28.jpg|left]]<br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>
<br>[[Image:Fig_R28.jpg|left]]<br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>
'''''Fig. R28:''' Example of inductive coupling''  
'''''Fig. R38:''' Example of inductive coupling''  


----


== Counter-measures ==
== Counter-measures ==
Line 39: Line 38:
*Reduce the dv/dt of the disturber by increasing the signal rise time where possible (series-connected resistors or PTC resistors on the disturbing cable, ferrite rings on the disturbing and/or victim cable)
*Reduce the dv/dt of the disturber by increasing the signal rise time where possible (series-connected resistors or PTC resistors on the disturbing cable, ferrite rings on the disturbing and/or victim cable)


&nbsp;
 


[[ru:Индуктивная связь]]
[[ru:Индуктивная связь]]
[[zh:电感耦合]]
[[zh:电感耦合]]

Revision as of 14:29, 19 October 2013

Definition

The disturber and the victim are coupled by a magnetic field. The level of disturbance depends on the current variations (di/dt) and the mutual coupling inductance.
Inductive coupling increases with:

  • The frequency
  • The proximity of the disturber to the victim and the length of the parallel cables,
  • The height of the cables with respect to a ground referencing plane,
  • The load impedance of the disturbing circuit.

Examples

(see Fig. R38)

  • Nearby cables subjected to rapid current variations (di/dt)
  • Short-circuits
  • Fault currents
  • Lightning strikes
  • Stator control systems
  • Welding machines
  • Inductors


Fig R28.jpg
















Fig. R38: Example of inductive coupling


Counter-measures

  • Limit the length of parallel runs of disturbers and victims to the strict minimum
  • Increase the distance between the disturber and the victim
  • For two-wire connections, run the two wires as close together as possible
  • Use multi-core or touching single-core cables, preferably in a triangular layout
  • Position a PEC bonded at both ends and between the disturber and the victim
  • Use symmetrical transmission systems on correctly implemented, symmetrical wiring systems
  • Shield the disturbing cables, the victim cables or both (the shielding must be bonded)
  • Reduce the dv/dt of the disturber by increasing the signal rise time where possible (series-connected resistors or PTC resistors on the disturbing cable, ferrite rings on the disturbing and/or victim cable)