Circuit-breaker: Difference between revisions

From Electrical Installation Guide
(Cleanup_2016)
(Table H23 - improved formating (cleanup_2016))
Line 11: Line 11:
|-
|-
! colspan="2" | Functions  
! colspan="2" | Functions  
! Possible Conditions  
! colspan="2" | Possible Conditions  
|-
|-
| colspan="2" | Isolation
| colspan="2" | Isolation
|  
| {{BlueSquare}}
*
|
|-
|-
|-
| rowspan="3" |Control
| rowspan="3" |Control
| Functional
| Functional
|  
| {{BlueSquare}}
*
|
|-
|-
| Emergency switching
| Emergency switching
|  
| {{EmptyBlueSquare}}
*(With the possibility of a tripping coil for remote control)
| (With the possibility of a tripping coil for remote control)
|-
|-
| Switching-off for mechanical maintenance
| Switching-off for mechanical maintenance
|  
| {{BlueSquare}}
*
|
|-
|-
| rowspan="4" | Protection
| rowspan="4" | Protection
| Overload
| Overload
|  
| {{BlueSquare}}
*
|
|-
|-
| Short-circuit
| Short-circuit
|  
| {{BlueSquare}}
*
|
|-
|-
| Insulation fault
| Insulation fault
|  
| {{EmptyBlueSquare}}
*(With differential-current relay)
| (With differential-current relay)
|-
|-
| Undervoltage
| Undervoltage
|  
| {{EmptyBlueSquare}}
*(With undervoltage-trip coil)
| (With undervoltage-trip coil)
|-
|-
| colspan="2" | Remote control
| colspan="2" | Remote control
|  
| {{EmptyBlueSquare}}
* Added or incorporated
| Added or incorporated
|-
|-
| colspan="2" | Indication and measurement
| colspan="2" | Indication and measurement
|  
| {{EmptyBlueSquare}}
*(Generally optional with an electronic tripping device)
| (Generally optional with an electronic tripping device)
|-
|-
{{TableEnd|Tab1265|H23|Functions performed by a circuit-breaker/disconnector}}
{{TableEnd|Tab1265|H23|Functions performed by a circuit-breaker/disconnector}}

Revision as of 13:44, 29 December 2016


The circuit-breaker/disconnector fulfills all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist

As shown in Figure H23 the circuit-breaker/ disconnector is the only item of switchgear capable of simultaneously satisfying all the basic functions necessary in an electrical installation.

Moreover, it can, by means of auxiliary units, provide a wide range of other functions, for example: indication (on-off - tripped on fault); undervoltage tripping; remote control… etc. These features make a circuit-breaker/ disconnector the basic unit of switchgear for any electrical installation.

Functions Possible Conditions
Isolation [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Control Functional [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Emergency switching [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (With the possibility of a tripping coil for remote control)
Switching-off for mechanical maintenance [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Protection Overload [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Short-circuit [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\blacksquare }[/math]
Insulation fault [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (With differential-current relay)
Undervoltage [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (With undervoltage-trip coil)
Remote control [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] Added or incorporated
Indication and measurement [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}\definecolor{myblue}{rgb}{0.26,0.71,0.9}\color{myblue}\square }[/math] (Generally optional with an electronic tripping device)
Fig. H23 – Functions performed by a circuit-breaker/disconnector