| bgcolor="#0099cc" | The circuit-breaker/disconnector fulfills all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist
|}
 
 
As shown in '''Figure H23''' the circuit-breaker/ disconnector is the only item of switchgear capable of simultaneously satisfying all the basic functions necessary in an electrical installation.
 
Moreover, it can, by means of auxiliary units, provide a wide range of other functions, for example: indication (on-off - tripped on fault); undervoltage tripping; remote control… etc. These features make a circuit-breaker/ disconnector the basic unit of switchgear for any electrical installation.
 
 
{| style="width: 600px; height: 100px" cellspacing="1" cellpadding="1" width="65%" border="1"
|-
| bgcolor="#0099cc" | '''Functions'''
| bgcolor="#0099cc" |   
| bgcolor="#0099cc" | '''Possible Conditions'''
|-
| Isolation
|  
|
*
|-
|-
| Control
| Functional
|
*
|-
|-
|  
| Emergency switching
|
*(With the possibility of a tripping coil for remote control)
|-
|-
|  
| Switching-off for mechanical maintenance
|
*
|-
|-
| Protection
| Overload
|
*
|-
|-
|  
| Short-circuit
|
*
|-
|-
|  
| Insulation fault
|
*(With differential-current relay)
|-
|-
|  
| Undervoltage
|
*(With undervoltage-trip coil)
|-
|-
| Remote control
|  
|
* Added or incorporated
|-
|-
| Indication and measurement
|  
|
*(Generally optional with an electronic tripping device)
|-
|}
 
'''''Fig. H23:''' Functions performed by a circuit-breaker/disconnector''
 
 


{| cellpadding="1" style="border: 1px solid #8888aa; background: #f7f8ff; padding: 5px; "
{| cellpadding="1" style="border: 1px solid #8888aa; background: #f7f8ff; padding: 5px; "
Line 10: Line 92:
* [[Coordination between circuit-breakers]]
* [[Coordination between circuit-breakers]]
* [[Discrimination MV/LV in a consumer’s substation]]
* [[Discrimination MV/LV in a consumer’s substation]]
* [[Circuit-breakers suitable for IT systems]]
* [[Ultra-rapid circuit breaker]]
* [[Ultra-rapid circuit breaker]]
|}
|}


[[ru:Автоматический выключатель]]
 
 
<br>[[ru:Автоматический выключатель]]
[[zh:断路器]]
[[zh:断路器]]

Revision as of 11:19, 20 August 2013


The circuit-breaker/disconnector fulfills all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist


As shown in Figure H23 the circuit-breaker/ disconnector is the only item of switchgear capable of simultaneously satisfying all the basic functions necessary in an electrical installation.

Moreover, it can, by means of auxiliary units, provide a wide range of other functions, for example: indication (on-off - tripped on fault); undervoltage tripping; remote control… etc. These features make a circuit-breaker/ disconnector the basic unit of switchgear for any electrical installation.


Functions   Possible Conditions
Isolation  
Control Functional
  Emergency switching
  • (With the possibility of a tripping coil for remote control)
  Switching-off for mechanical maintenance
Protection Overload
  Short-circuit
  Insulation fault
  • (With differential-current relay)
  Undervoltage
  • (With undervoltage-trip coil)
Remote control  
  • Added or incorporated
Indication and measurement  
  • (Generally optional with an electronic tripping device)

Fig. H23: Functions performed by a circuit-breaker/disconnector


Contents:



ru:Автоматический выключатель zh:断路器

Share