Practical values of power factor

From Electrical Installation Guide
Revision as of 15:51, 23 August 2013 by Jschonek (talk | contribs) (updated according to guide 2013)

Home > Power Factor Correction > Power factor and Reactive power > Practical values of power factor


Average power factor values for the most commonly-used equipment and appliances

(see Fig. L6)

Equipment and appliances cos φ tan φ
  • Common induction motor
loaded at

0%

25%

50%

75%

100%

0.17

0.55

0.73

0.80

0.85

5.80

1.52

0.94

0.75

0.62

  • Incandescent lamps
  • Fluorescent lamps (uncompensated)
  • Fluorescent lamps (compensated)
  • Discharge lamps
   

1.0
0.5
0.93
0.4 to 0.6

0
1.73
0.39
2.29 to 1.33

  • Ovens using resistance elements
  • Induction heating ovens (compensated)
  • Dielectric type heating ovens
   

1.0
0.85
0.85

0
0.62
0.62

  • Resistance-type soldering machines
  • Fixed 1-phase arc-welding set
  • Arc-welding motor-generating set
  • Arc-welding transformer-rectifier set
   

0.8 to 0.9
0.5
0.7 to 0.9
0.7 to 0.8

0.75 to 0.48
1.73
1.02 to 0.48
1.02 to 0.75

  • Arc furnace
    0.8 0.75


Fig. L6: Values of cos φ and tan φ for commonly-used equipment